MODEL | MIRACLE – 24CHSA/VEI | ||
Nominal cooling efficiency | W | 6.700(1.830~7.820) | |
Btu/h | 22.850(6.250~26.700) | ||
Rated heating efficiency | W | 6.810(1.850~7.960) | |
Btu/h | 23.250(6.300~27.150) | ||
Design load (cooling) | W | 6700 | |
Design load (heating) | W | 5600 | |
Nominal SEER (cooling) | W/W | 6,1 | |
Energy class (cooling) | A ++ | ||
Nominal SCOP (heating, middle zone) | W/W | 4,0 | |
Energy class (heating, middle zone) | A + | ||
Nominal SCOP (heating, hot zone) | W/W | 5,1 | |
Energy class (heating, hot zone) | A +++ | ||
Annual energy consumption | Cooling | kwh/a | 384 |
Heating | kwh/a | 1537 | |
Dehumidification | Liters/h | 1,8 | |
Sound power level (interior) (H/M/L/Mute) | dB(A) | 57/52/48/44/41 | |
Sound power level (abroad) | dB(A) | 67 | |
Sound pressure level (interior) (H/M/L/Mute) | dB(A) | 47/42/38/34/31 | |
Sound pressure level (abroad) | dB(A) | 57 | |
ELECTRICAL ELEMENTS | |||
Power supply | 220-240V~/50Hz/1P | ||
Operating voltage range | V | 165~265 | |
Operating current | Cooling | A | 10.8(2.3~13.0) |
Heating | A | 9.4(2.3~14.0) | |
Power consumption | Cooling | W | 2115(410~2800) |
Heating | W | 1836(420~3000) | |
COOLING CIRCUIT | |||
Refrigerant / Quantity / GWP / CO2 Equivalent | R32/1.16kg/675/0.554tonnes | ||
Compressor | Type | Rotary | |
Air flow (cooling heating) | m3/h | 1050/1050 | |
CONNECTIONS | |||
Cooling piping | Gas | Inches | 1/2” |
Liquid | Inches | 1/4” | |
Electrical connection | Power supply cable | 3*2,5mm² / εσωτ. Unit | |
Communication cable | 4*1,5mm² | ||
Electr. Security (A) | 16 | ||
OTHER | |||
Maximum length of cooling pipes | m | 25 | |
Maximum altitude difference | m | 10 | |
Operating temperature range | °C | 16-31 | |
Ambient temperature operating range | External | mm | Cooling:-15-53/Heating:-20-30 |
Indoor | mm | Cooling:17-32/Heating:0-30 | |
Net dimensions (Π x Υ x B) | Indoor | mm | 1095×327×235 |
External | mm | 920×699×380 | |
Net weight | Indoor | kg | 14 |
External | kg | 40 |